Permit: T12CM01373

Parcel: 138043610


Addresses:

841 W CALLE BOCINA

Inspection Status: Approved

Inspection History: BUILDING - PROGRESS

Date Description Inspector Results Comments
11/20/2012 BUILDING - PROGRESS Approved IVRS - Inspection :*
10/24/2012 BUILDING - PROGRESS Partial Approval EXCEPT NOTES 2+8 FROM PREVIOUS
10/18/2012 BUILDING - PROGRESS Denied NOTES 1-3, & 7-8 ON PREVIOUS INSPECTION
08/10/2012 BUILDING - PROGRESS Partial Approval SHEET ROCK NAILING BATHROOM OK
08/02/2012 BUILDING - PROGRESS Partial Approval 1) SHEET ROCK NAILING IN DINING ROOM AND MASTER BATHROOM OK
07/24/2012 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
07/03/2012 BUILDING - PROGRESS Not ready for Inspection IVRS - Inspection :*
PROVIDE TEST ABS
06/19/2012 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
05/21/2012 BUILDING - PROGRESS Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE PROPERTY PINS TO VERIFY 20" SET BACK CARPORT COLLAR TIES OR LU26 HANGERS H2.5 RAFTER TO BEAM AT CARPORT
2) REAR PORCH HEADER 4 X 6 OVER SPANNED. ADD POSTS. EXPOSE FOOTERS TO VERIFY DEPTH. LU26 A FASCIA ATTACHMENT WITH FHA STRAP
3) ADD NEW KITCHEN ELECTRICAL TO PLAN. EXPOSE FOR INSPECTION
4) PROVIDE 10' HEAD TEST ALL ABS ROUGH SOIL
5) BATH ELECTRICAL NOT READY
6) EXPOSE ELECTRICAL IN SUITE OR PROVIDE LETTER HEAD FROM LICENSED ELECTRICAL CONTRACTOR STATING ALL WORK TO CODE FOR SAFETY
7) EXPOSE WALL TO RAFTER CONNECTIONS
8) CONSULT WITH TEP CABLE DROP AT REAR PORCH 30" ROOF FLAT