Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/11/2012 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
| 04/03/2012 | ELECTRIC - RECONNECT | Partial Approval | IVRS - Inspection :* 1) BREAKERS TO BE SAME AS PANEL MANUFACTURE 2) SEAL ENTRANCES ABOVE CORRECT CARRING PARTS WITH APPROVED DEVICES |
|
| 04/02/2012 | ELECTRIC - RECONNECT | Not ready for Inspection | IVRS - Inspection :* | |
| 03/21/2012 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GROUNDING ELECTRODE CONDUCTOR, WATER BOND CUT/MISSING 2) NEED SMOKE DETECTOR IN ALL BEDROOMS AND INSTALL PER MANUFACTURERS INSTRUCTIONS 3) GROUNDED RECEPTS ON NON GROUNDED CIRCUITS 4) MISSING KITCHEN COUNTER RECEPT-WILL NEED TO BE GFCI PROTECTED |