Permit: T12CM01179

Parcel: 119411510


Addresses:

2043 W AJO WY

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
07/12/2012 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
07/11/2012 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
07/05/2012 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
NOTES 3, 4, 5, 6, & 7 FROM PREVIOUS
NEXT DENIAL WILL RESULT IN A REFEE
ANY CHANGES TO SERVICE REQUIRE AS-BUILT
06/01/2012 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING EXT. GFCI'S
2) MISSING OUTLET AND EXT. LIGHT FIXTURE MASTER BEDROOM
3) SECURE ALL ROMEX 8" FROM BOXES
4) PROVIDE 2-20 AMP APPLIANCE CIRCUITS KITCHEN
5) PROVIDE DEDICATED REFRIDGE CIRCUIT
6) SMOKE ALARM OPPOSITE SIDE MASTER BEDROOM
7) HAVE QUALIFIED ELECTRICIAN CLEAN UP MAIN SERVICE PANEL TO CODE
8) TO MANY VIOLATIONS TO LIST
05/31/2012 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) PROVIDE ACCESS