Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/25/2012 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
| 04/06/2012 | ELECTRIC - RECONNECT | Not ready for Inspection | IVRS - Inspection :* 1) SERVICE LEFT TO BE INSPECTED ONLY 2) HOUSE INSIDE OK |
|
| 03/30/2012 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 03/19/2012 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE A SMOKE DETECTOR IN EACH BEDROOM 2) OUTDOOR RECEPT MUST BE GFI 3) DBL LUGGING AND TRIPLE LUGGING NOT ALLOWED IN SERVICE DISCONNECT 4) N.M. CABLE AT SERVICE DISCONNECT NOT APPROVED FOR DIRECT EXPOSURE TO SUNLIGHT 5) USE PROPER FITTING FOR N.M. CABLE TO DISCONNECT BOX 6) PLEASE PROVIDE A QUALIFIED ELECTRICIAN FOR THIS REPAIR 7) EXPOSED ROMEX AT FLOOD LIGHT ON PATIO 8) INCORRECT WIRING METHODS AT CARPORT PORCH LIGHT 9) BROKEN COVER PLATE IN STORAGE ROOM |