Permit: T12CM01005

Parcel: 11942006L

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
03/14/2012 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
03/13/2012 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE WEATHERED COVER EXTERIOR GFCI
2) SEAL AND SECURE LIQUID TIGHT AT CONDENSOR DISCONNECT
3) SMOKE ALARM BEDROOMS
4) SECURE LIVING ROOM OUTLET EAST WALL TO CODE. TERMINATE INSULATION 1/4" INTO BOX
5) WHITE A/C HOT LEAD 50 AMP BREAKER MUST BE RED OR BLACK (TAPE OK)