Permit: T12CM00933

Parcel: 115044910


Addresses:

1020 N TYNDALL AV


Inspection Status: Approved

Inspection History: STEM WALL/RETAINING WALL

Permit Number - T12CM00933

Inspection Description - STEM WALL/RETAINING WALL

Inspection Status - Approved

Date Description Inspector Results Comments
08/14/2013 STEM WALL/RETAINING WALL Approved SEE T12CM02811 FOR ALL FINAL INSPECTION RESULTS
08/29/2012 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
08/27/2012 STEM WALL/RETAINING WALL Partial Approval LEVEL 3 17 COLUMES 6-9/ATHLER E. 5/D AND 5/E
08/24/2012 STEM WALL/RETAINING WALL Partial Approval SHEAR WALL 6 LEVEL 2. OK
08/23/2012 STEM WALL/RETAINING WALL Partial Approval CP;I,E AT 5D/ AS PER RFI #098R1
08/22/2012 STEM WALL/RETAINING WALL Partial Approval SHEARWALL #7 AT 2ND LEVEL. COLUME AT 5/E. 2ND LEVEL
08/21/2012 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
08/20/2012 STEM WALL/RETAINING WALL Not ready for Inspection SHEARWALL #5 4TH FLOOR ONE SIDE
08/17/2012 STEM WALL/RETAINING WALL Partial Approval LEVEL 2-3
A-6, B-6, A-7, B-7, A-8, B-8, A-9, B-9, C-9, D-9, E-9, E-8, E-7.1, D-6
ALL OK TO POUR
08/16/2012 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
08/13/2012 STEM WALL/RETAINING WALL Partial Approval SHEARWALL 6 1ST FLOOR AS PER DETAIL 1P SW 1K
08/10/2012 STEM WALL/RETAINING WALL Partial Approval GL 3/E COLUME AND LEVEL 1
08/09/2012 STEM WALL/RETAINING WALL Partial Approval SHEARWALL 2,4.4 3RD LEVEL. COLUMES. D/1, E/1, E/4, A-2/3
08/08/2012 STEM WALL/RETAINING WALL Partial Approval SHEARWALL 7. 3RD FLOOR GL 4/A-D COLUMS 3/A-C, 2/A-C
1/A-C ALL COLUMNS, SHEARWALL 2 3RD FLOOR
08/07/2012 STEM WALL/RETAINING WALL Partial Approval SHEARWALL #1 AND 3 3RD FLOOR CORE
08/06/2012 STEM WALL/RETAINING WALL Partial Approval SHEAR WALL 4 AND 5 AT LEVEL 3
08/03/2012 STEM WALL/RETAINING WALL Not ready for Inspection IVRS - Inspection :*
08/01/2012 STEM WALL/RETAINING WALL Partial Approval SHEAR WALL #2. OK TO POUR 2ND TO 3RD FLOOR CORE.
07/31/2012 STEM WALL/RETAINING WALL Partial Approval GL 5/A-A.Z, C,D,E, 61A,A.2,C,D,E COLUMN P1 7/A-A.1, 6/E, E/7.1, E/8, E/9, D/9, C/9, A.1/9, A/9, A/8
07/30/2012 STEM WALL/RETAINING WALL Partial Approval SHEAR WALL 1,3,4 2ND TO 3RD FLOOR CORE
07/26/2012 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
SHEAR WALL #5 2ND TO 3RD FLOOR. B2 COLUMN 1ST FLOOR
07/24/2012 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
B-2 & C-2 COLUMES
07/20/2012 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
PT IN SAEAR WALL 1 & 2
1ST TO 2ND FLOOR
07/19/2012 STEM WALL/RETAINING WALL Not ready for Inspection IVRS - Inspection :*
07/18/2012 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
SHEARWALL #2 1ST TO 2ND FLOOR
07/17/2012 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
SHEAR WALL #1 1ST TO 2ND LEVEL
2ND INSPECTION PM
07/16/2012 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
AZ SHEARWALL 3 & 4 1ST FLOOR
07/15/2012 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
A/9, E/9 COLUMES
07/13/2012 STEM WALL/RETAINING WALL Partial Approval COLS @ A/9; B/4; B/6 (NEEDS RFI); E/2; E/3; E/4 OK TO CLOSE
B/6 WILL REQUIRE AN RFI RESPONSE FROM ENGINEER ADDRESSING NON-ALIGNED LAP SPLICES FROM FOOTING TO COLUMN. CONDITION DOESN'T QUITE CONFORM TO ACI 12.14.2.3, (NONCONTACT LAP SPLICE ALLOWED SMALLER OF 1/5 LAP LENGTH OR 6")
07/11/2012 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
GL E/6 E/7.1 E/8 9-8 A,9 A-A1 6/A.2 6/C 6/D 6/E 5/A 5/A.2
07/09/2012 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
GL 2/C-D SWG
D.8 E.5 /9
07/06/2012 STEM WALL/RETAINING WALL Partial Approval OK TO CLOSE SW7 & COLS @ A2/7,8
07/05/2012 STEM WALL/RETAINING WALL Partial Approval BASEMENT TO LEVEL 1 FOLLOWING AREAS:
LINE E.5 / 5-9;
LINE 9 / A - E<20>;
ELEVATOR CORE OK TO CLOSE, OK TO PLACE WHEN SPECIAL INSP CONFIRMS SW5 MECH CHASE PLACEMENT PER RFI.

COLS AT A/5,6,7,8 OK TO CLOSE; OK TO PLACE WHEN SP INSP CONFIRMS FORM SET.
07/03/2012 STEM WALL/RETAINING WALL Partial Approval ELEVATOR CORE. NEED RFI FOR RELOCATING MECH DUCT IN SW5
07/02/2012 STEM WALL/RETAINING WALL Partial Approval 1/A-E,2/A.Z,2/L,2/E,3/A-A.2,3/L,3/E,4/A-A.2,4/C,4/D