Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/30/2012 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 04/27/2012 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 04/19/2012 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* *PLEASE VERIFY QUALIFIED ELECTRICAL PERSON - THEY NEED TO GO THROUGH ENTIRE STRUCTURE AND CORRECT ANY DISCREPANCIES AT SERVICE: 1. CORRECTLY IDENTIFY GROUNDED CONDUCTOR 2. ONLY ONE CONDUCTOR TO TERMINAL LOG 3. FILL UNUSED OPENINGS 4. MAINTAIN WORKING SPACE 5. PROVIDE GROUDING ELECTRODE SYSTEM 6. NEEDS GAS + WATER BOND, CLAMP NOT EFFECTIVE HOUSE: 1. STRAPS TO BE ANCHORED 2. FUSES TO LARGE FOR CONDUCTOR AMPACITY 3. CONDUIT IN BATH ROOM TO BE FOR ELECTRIC NOT WATER 4. INSTALL SMOKE DETECTOR PER MANUFACTURES INSTRUCTIONS |
|
| 03/08/2012 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* |