Inspection History: PLUMBING - FINAL
Permit Number - T12CM00869
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/29/2012 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
03/26/2012 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) #2 BOND NEEDS TO BE TIED INTO THE ELECTRIC SERVICE PANEL |
|
03/09/2012 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) NEED TO BOND NEW GAS LINE 2) ALL METALIC PIPE NEEDS TO BE BONDED TO SERVICE 3) ISSUED GAS TAG |