Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T12CM00722

Parcel: 12504079A


Addresses:

1900 E SPEEDWAY BL


Inspection Status: Approved

Inspection History: ENGINEERING - FINAL

Permit Number - T12CM00722

Inspection Description - ENGINEERING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
03/07/2013 ENGINEERING - FINAL Approved 1) PICTURES TAKEN OF NON-CONFORMING PARKING AREA.
2) PARKING AREA IS EXISTING AND DUE TO THE FACT THAT THE CONTRACTOR WAS NOT TASKED TO COMPLETE NEW SITE WORK OUTSIDE THE FOOT PRINT OF THE BLDG, SITE CORRECTIONS ARE NOT REQUIRED.
03/06/2013 ENGINEERING - FINAL Partial Approval FINAL APPROVAL WILL NOT BE GIVEN UNTIL SITE NON-COMPLIANCE IS APPROVED.
CONSTRUCTION WAS COMPLETED PER APPROVED PLAN; HOWEVER PARKING AREA AROUND HOTEL DOES NOT MEET TRAVEL LANE REQUIREMENTS FOR THE PAAL
03/04/2013 ENGINEERING - FINAL Continued 1) NO VERTICAL SEPARATION BETWEEN THE PAAL AND THE SIDEWALK ALONG CAMPBELL AND SPEEDWAY.
2) STORM DRAINAGE WILL PUDDLE AT HC RAMP ALONG SPEEDWAY. RAMP IS A LOWW SPOT IN CURB LINE
3) NO HC PARKING SIGNS
4) THE ALLEY/EASEMENT AT THE SOUTH SIDE OF THE SITE IS NOT COMPLETE
5) LANDSCAPING NOT COMPLETE
02/11/2013 ENGINEERING - FINAL Continued SITE WORK NOT COMPLETED, TO INCLUDE PARKING LOT, TRASH ENCLOSURE, SIDEWALKS, AND HC RAMPS.

1) NO ENG PRE-CON CALLED IN.
2) NO SITE INSPECTIONS CALLED IN.
3) SITE HAS SWPPP, HOWEVER SWPP WAS NEVER IMPLEMENTED OR INSPECTED. SWPPP SAYS SITE DISTURBANCE IS 1.1 ACRES, NO NOI ON SITE.
4) PAAL WIDTH IS AS NARROW AS 14 FEET, HOWEVER TWO WAY TRAVEL IS SHOWN ON PLAN.
5) TRASH ENCLOSURE WIDTH ON APPROVED PLAN SHOWS 24'-8", ENCLOSURE WAS BUILT AT 21'
6) STORM DRAIN CATCH BASIN SHOWN ON APPROVED PLANS WAS NOT INSPECTED.
7) ALL PERMITS WITH ENGINEERING INSPECTIONS ON THEM INCLUDE: DP11-0018, T12CM00722, T12CM01919, AND DP12-0037 (ADJACENT PARKING).
8) NPPO WAS NEVER IMPLEMENTED
9) SITE PLAN SHOWS A 4' MIN SIDEWALK W/ A 2.5' VEHICLE OVERHANG, LEAVING A 1.5' PEDESTRIAN PATHWAY. ADA REQUIRES A MIN 36" CLEAR PATH FOR ACCESS.