Permit: T12CM00618

Parcel: 122100210


Addresses:

1511 N DESMOND AV

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
03/02/2012 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
02/29/2012 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE LISTED ROOF FLASHINGS (ROOF JACKS) AT EACH ROOF PENETRATION-RETEST SYSTEM
2) WATER HEATER VENT IS REQUIRED TO TERMINATE ABOVE COOLER WITH TYPE B VENTING
3) SECURE CONNECTORS WITH SCREWS AND PROPER ALIGNMENT
4) ELECTRICAL BONDING IS REQUIRED
5) PROVIDE CITY APPROVED RELIEF VALVE TERMINATION TO EXTERIOR OR INTO PAN
6) SECURE PIPING NEAR SHUT OFF VALVES
7) SEDIMENT TRAPS REQUIRED