Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/14/2012 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* 1) LEFT MSG. 12:20 PM |
|
| 02/29/2012 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO COMPLIANCE WITH NOTES 2, 5 & 10 |
|
| 02/27/2012 | ELECTRIC - RECONNECT | Not ready for Inspection | IVRS - Inspection :* | |
| 02/24/2012 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FRONT PORCH LIGHT BROKEN ABND NOT PROPERLY INSTALLED 2) PROVIDE BLANK OFFS AT BREAKER PANEL 3) PROVIDE CORRECT FITTINGS ON EMT, ELECTRICAL TAPE NOT AN APPROVED METHOD 4) PROVIDE WEATHER RESISTANT BOXES AND FITTINGS ON EXTERIOR 5) GROUNDING WIRE TO UFER MISSING 6) BARE WIRING IN LIVING SPACES 7) LIGHT FIXTURE BURRIED IN CEILING WITH JOINT COMPOUND 8) THIS IS AN UNGROUNDED SYSTEM, REPLACE ALL GROUNDED OUTLET WITH UNGROUNDED OUTLETS 9) PROVIDE HEATING UNIT AND WATER HEATER PRIOR OCCUPANCY 10) BREAKER AT INTERIOR SUB PANEL IS BROKEN, NEEDS TO BE REPLACED, PROVIDE BLANK OFF AT SAME PANEL 11) REMOVE ALL BOARDS FROM WINDOWS PRIOR TO OCCUPANCY |