Permit: T12CM00530

Parcel: 140152130


Addresses:

2133 E CANADA ST


Inspection Status: Partial Approval

Inspection History: ELECTRIC - RECONNECT

Permit Number - T12CM00530

Inspection Description - ELECTRIC - RECONNECT

Inspection Status - Partial Approval

Date Description Inspector Results Comments
03/02/2012 ELECTRIC - RECONNECT Partial Approval IVRS - Inspection :*
1) STILL NEED SMOKE DETECTORS PER LAST INSPECTION
02/22/2012 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GROUND RODS NEED TO BE 6' MINIMUM APART AND NO MORE THAN 45 DEGREE ANGLE
2) EXPOSED ROMEX INSIDE DUE TO DRYWALL REPAIR, SUPPORT AT 12" FROM BOX, ALSO ROMEX IN EAST ROOM WITH T-BAR CEILING NOT TO CODE
3) SMOKE DETECTORS REQUIRED IN HALLWAY AND ALL BEDROOMS
4) USE QUALIFIED OR LICENSED ELECTRICIAN TO DO WORK