Permit: T12CM00517

Parcel: 136331050


Addresses:

9400 E 39TH ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
03/29/2012 ELECTRIC - FINAL Approved IVRS - Inspection :*
02/22/2012 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEAL OPEN KNOCKOUTS IN TOP AND BOTTOM OF CIRCUIT PANEL
2) BE SURE TO USE AN APPROVED FITTING AND ALSO FILL IN COVER PLATE WHERE BREAKERS ARE MISSING
3) ROMEX FROM PANEL UP TO EAVES CANNOT BE EXPOSED TO SUN LIGHT
4) ALL OUTDOOR RECEPTS MUST BE GFI PROTECTED
5) RE-INSTALL J BOX AT RECEPT FOR GARBAGE DISPOSAL