Permit: T12CM00508

Parcel: 12404102B

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
04/10/2012 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
04/09/2012 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
04/05/2012 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1) EACH FIXTURE TRAP SHALL HAVE A CONNECTING VENT LOCATED DOWNSTREAM OF THE TRAP
2) EACH VENT CONNECTED TO A HORIZONTAL DRAIN, SHALL HAVE IT'S INVERT TAKEN OFF ABOVE THE DRAINAGE CENTER LINE
3) ISOLATE ABS FROM METAL STUDS, KEEP SEWER CONNECTED VENTS CAPPED
04/02/2012 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*