Permit: T12CM00487

Parcel: 130170770


Addresses:

4025 E 27TH ST

Inspection Status: Approved

Inspection History: ELECTRIC - SERVICE UPGRADE

Date Description Inspector Results Comments
04/04/2012 ELECTRIC - SERVICE UPGRADE Approved IVRS - Inspection :*
03/28/2012 ELECTRIC - SERVICE UPGRADE Partial Approval IVRS - Inspection :*
1) SUB PANEL GROUNDS AND NEUTRALS TO BE SEPERATED AND K.O. SEALS PLUGGED
03/27/2012 ELECTRIC - SERVICE UPGRADE Not ready for Inspection IVRS - Inspection :*
1) PROVIDE MINIMUM OF 2 CLAMPS ON RISER SUPPORT
2) REMOVE GREEN PLASTIC PROTECTIVE COATING FROM GAS PIPE BEFORE ATTACHING BONDING CLAMP
3) BREAKERS IN PANEL ARE TO BE OF SAME BRAND AS PANEL, AS INDICATED ON PANEL NAME PLATE