Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T12CM00471
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/15/2012 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 03/14/2012 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COIL STRAP MISSING FOR ACROSS TOP OF BEAM TO PLATE PER 6/S5.1 2) BLOCK BETWEEN TRUSSES AT TOP PLATE PER 8/S5.4 3) 4 X 4 BLOCKING MISSING PER 1/S5.4 DETAIL AT GARAGE 4) BLOCKING MISSING PER 12/S5.4 |