Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: T12CM00380

Parcel: 135074470


Addresses:

1470 S EASTSIDE LP

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
09/16/2013 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
08/13/2013 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
08/13/2013 PLUMBING - ROUGH, SOIL Denied - SAN TEE NOT APPROVED FOR HORIZ INSTALL. ALSO, POINT OF VENT SHALL BE ABOVE OF DRAIN PIPE SERVED
- CORRECT SIZING AT URINALS AND SINKS