Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T12CM00289
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/17/2012 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
04/13/2012 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) P3005.2.9 2006 IRC INSTALL 2 WAY CLEANOUT SHOWN FOR GREY BLDG DRIAN 2) 3" DRAIN REQUIRES 3" CLEANOUT 3) REMOVE ROCKS TOUCHING PIPE THAT ARE LARGER THAN 5/8" 4) PIPING SHALL BE LAID ON A FIRM COMPACTED BED WITH ONLY BELL HOLES UNDER JOINTS P-2605.1/2604.1/2604.3 AND 2503.5.1 |