Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
| Date |
Description |
Inspector |
Results |
Comments |
| 08/01/2013 |
PLUMBING - SEWER HCS CONNECT |
|
Approved |
|
| 07/25/2012 |
PLUMBING - SEWER HCS CONNECT |
|
Partial Approval |
1. This inspection is for 4" ABS sewer from bldg. drain to property line cleanout. Will require full size upper terminal cleanout. ABS to be laid on a firm bed, no bridging permitted. Require #18 green tracer wire. |
| 07/25/2012 |
PLUMBING - SEWER HCS CONNECT |
|
Not ready for Inspection |
1. Backpitched sections not permitted. Have torpedo level on site for grade verification. |