Permit: T12CM00168

Parcel: 13409018E


Addresses:

8640 E BROADWAY BL


Inspection Status: Not ready for Inspection

Inspection History: PLUMBING - PROGRESS

Permit Number - T12CM00168

Inspection Description - PLUMBING - PROGRESS

Inspection Status - Not ready for Inspection

Date Description Inspector Results Comments
04/12/2013 PLUMBING - PROGRESS Not ready for Inspection IVRS - Inspection :*
04/12/2013 PLUMBING - PROGRESS Approved IVRS - Inspection :*
04/12/2013 PLUMBING - PROGRESS Not ready for Inspection NON POTABLE HOSE BIB CAP OR SIGN FREEZE PROTCTION. TEST REPORT
04/11/2013 PLUMBING - PROGRESS Partial Approval IVRS - Inspection :*
04/10/2013 PLUMBING - PROGRESS Partial Approval IVRS - Inspection :*
04/09/2013 PLUMBING - PROGRESS Partial Approval PROVIDE BACKFLOW PROTECTION BE HYBRID COOLING TOWER 2/ CHSM FOES, AS REQUIRED PER 608.1. PROVIDE CLEAN OUT AT 360 DEGREE CHANGE OF DIRECTION IN OVERHEAD DRAIN OR REMOVE 90 DEGREE FITTINGS. CONNECT RO DRAIN AND PHARMACY TO TAIL PIECE UP STRM OF TRAPS.
PROVIDE PROPER TRANSITION FORM CPVC AT MAIN RO SYSTEM, APPROVED SUPPORTS ON DRAIN. CORRECT LEAKS. UNDER LAVITORIES OK. PROVIDE APPROVED CO PLUGS.
04/01/2013 PLUMBING - PROGRESS Denied IVRS - Inspection :
See detailed listing on site.| 999*MISSING CLEAN OUT AT PHARMACY SINK. ALL CO PLUGS SHALL BE LISTED TO RECEIVE SCREWS REMOVE COVERS UNDER LAVS AND DFS. INSTALL TRAP SEAL DEVICES WHERE REQ. 1002.4 INSTALL GAS OVEN W/ SAFETY CABLE AND DRAIN. PROVIDE 2" AIR GAPS. PROVIDE ALL BACK FLOW ASSEMBLIES SHOWN ON PLAN: BOTH OVENS AND RO SYSTEM. PROVIDE STERILIZATION ON ALL WATER PIPING INCLUDING RO PIPING AND YARD WATER. SHOW DOCUMENTATION. TEST AND CERTIFY ALL BACKFLOW ASSEMBLIES. 312.9.2 REMOVE UNSAFE HOSEBIB. INSTALL VACUUM BREAKERS ON ALL HOSE BIBS. 2HR INSPECTION W/ TONE FROM SUNSLATE. RICK W/ WALMART AND STRAIGHT BUILD
03/28/2013 PLUMBING - PROGRESS Not ready for Inspection IVRS - Inspection :*
03/20/2013 PLUMBING - PROGRESS Denied IVRS - Inspection :
See detailed listing on site.| 999*
03/15/2013 PLUMBING - PROGRESS Denied IVRS - Inspection :
See detailed listing on site.| 999*
CALL FOR AND HAVE APPROVED ALL REQUIRED INSPECTIONS. YOUR INSP HISTORY SHOWS NO INTERMEDIATE APPROVALS FOR DMV TESTING. PROVIDE HISTORY FOR ALL AREAS OR PROVIDE A WATER TEST ON SYSTEM. ADDRESS ALL OUTSTANDING ISSUES. SEE HISTORY. REMOVE THE UNSAFE HOSE BIB LOCATED BELOW THE ROOF AT ACCESS HATCH. BIB IS NOT ACCESSIBLE AND HAS IMPROPER BACKFLOW DEVICE FOR THIS APPLICATION. EXTEND BTR TO 6' ABOVE HUMAN ACCESS AREA NEXT TO HATCH. PROTECT ALL PLASTIC FROM UVRAYS. COMPLETE WORK ABOVE CEILING. PROVIDE TRAP PRIMERS FOR ANY DRAINS THAT DO NOT RECEIVE CONTINUOUS DISCHARGE. TEST RO WATER SYSTEM AND CARBON DIAMOTOR CONDENSATE DRAINS.
03/13/2013 PLUMBING - PROGRESS Not ready for Inspection IVRS - Inspection :*
03/12/2013 PLUMBING - PROGRESS Not ready for Inspection IVRS - Inspection :*
01/24/2013 PLUMBING - PROGRESS Partial Approval IVRS - Inspection :*MENS, WOMENS, FAMILY RESTROOMS- OK TO INSULATE WALLS
01/23/2013 PLUMBING - PROGRESS Not ready for Inspection IVRS - Inspection :*CHANGE FROM LAST INSPECTION