Permit: T12CM00168

Parcel: 13409018E


Addresses:

8640 E BROADWAY BL

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
03/21/2013 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
01/28/2013 REINFORCED MASONRY PRE-GROUT Not ready for Inspection not ready contractor cancelled
eletric underground partial approx 600' of 1" conduit line for 5 parking lot pole lights- ok to cover progress area
01/24/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*7 PIER COLUMNS AT GL .5A/3.5-5.5 CART RETURN STEM WALL- GL: .5A/5-5.5
01/10/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CONSTRUCTION ENTRANCE OK TO GROUT AT 24" VESTIBULE MAIN ENTRY AREA/ CART STORAGE.
STORAGE -7 COLUMN STEM WALLS; CART STORAGE STEM WALL: GL .5A/ 5-5.75 COLUMNS GL: .5A/ 3.5-5.75- OK TO GROUT PROGRESS AREAS
01/09/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* VESTIBULE AREA- 7 COLUMN STEMS AT 32"; CART PARKING AREA WALL: GL: .5A/5-5.75 OK TO GROUT PROGRESS AREAS
11/14/2012 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 24': GL: 1/A-B.5; A/1-3.25; A/5-6; CMU WALLSAT 22' GL:1/B.5-D; 1/3.25-5; OK TO GROUT PROGRESS AREAS
11/09/2012 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 18'8"; GL: A11-3.25, 1/A- B-5 OK TO GROUT PROGRESS AREAS
11/06/2012 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL AT 9'4" GL: A/2.5-5 OK TO GROUT PROGRESS AREA
11/05/2012 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL AT 9'4"- GL: 6/A-D OK TO GROUT PROGRESS AREA
11/02/2012 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 9'4"-GL: A/ 1-3.25; A/ 5-6; CMU WALLS AT 14'8"- GL: 1/ D-C; D/ 1-3.4; D/5.1-6; CMU WALLS AT 16'-GL: 3.4/ D-E; E/ 3.4- 5.1; 5.1/ D-E: OK TO GROUT PROGRESS AREAS
11/01/2012 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 9'4" GL 1/A-D; D/1-2.25
AT 14': D/2.5-3.4; 3.4/D-E E/3.4-5.1; 5.1/D-E OK TO GROUT PROGRESS AREAS
10/30/2012 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 8'-GL: D/5-6; 5/D-E

*E/..4-5; 3.4/D-E; D/1.75-3.4: OK TO GROUT PROGRESS AREA PENDING VERIFICATION OF PROPER LAP SPLICE ON VERITICAL REBAR
10/29/2012 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 4' A.F.F.E GL:6/B.5-D; D/5-6; E/5-3.4; 3.4/D-E; D/3.4-2.25- OK TO GROUT PROGRESS AREAS
10/26/2012 REINFORCED MASONRY PRE-GROUT Partial Approval SMU WALLS AT 4'0 AFFE-GL: A/5.6; 6\A.B.5 OK TO GROUT PROGRESS AREAS
10/25/2012 REINFORCED MASONRY PRE-GROUT Partial Approval cmu walls at 0-48" affe gl 1/c-a ok to grout progress area
10/24/2012 REINFORCED MASONRY PRE-GROUT Partial Approval CONTINOUS STEM WALL GL:A/5-6;6/A-D D/1-6: 1/C.5-D