Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/12/2012 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 04/11/2012 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) H20 HAMMER ARRESTORS 2) DRY VENT HOOK UP 3) INSTALL BONDING JUMPERS ACROSS VIBRATION COLLAR 4) RE-RUN CONDENSATE AND TPR DRAIN 5) NEED DRIP LEGS ON GAS LINES 6) RAISE DISHWASHER DRAIN TO COUNTER |