Permit: T12CM00133

Parcel: 13813208A


Addresses:

208 W FINEDALE ST


Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T12CM00133

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
03/16/2012 BUILDING - FINAL Approved IVRS - Inspection :*
03/09/2012 BUILDING - FINAL Partial Approval IVRS - Inspection :*
1) FOOTERS OK TO POUR
2) GROUND METAL BOXES
3) SECURE ROMEX AT SWITCH BOX
4) RECEIVED MONEY ORDER FOR $82.50 (MONEY GRAM)
03/02/2012 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
1) CANCELLED
02/06/2012 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
02/01/2012 BUILDING - FINAL Denied 1) EXPOSE FOOTERS TO VERIFY DEPTH
2) STRUCTURES WITHIN 36" PROPERTY LINE EAST REQUIRES FIRE SEPERATION-FIRE WALL
3) EXPOSE ALL ELECTRICAL FOR INSPECTION OR PROVIDE LETTERHEAD FROM LICENSED CONTRACTOR STATING ALL WORK TO CODE FOR SAFETY
4) EXPOSE ALL WALL TO RAFTER CONNECTIONS
5) STORAGE ROOM UNDER 120' SQUARE FEET EAST WALL WITHIN 36" PROPERTY LINE EAST REQUIRES FIRE WALL EAST WALL
6) PER CODE SMOKE ALARM OPPOSITE SIDE BEDROOM DOOR
7) WEATHER PROOF EXTERIOR DOOR
8) LABEL ALL CIRCUITS PANEL