Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
Permit Number - T12CM00016
Inspection Description - PLUMBING - GAS PRESSURE TEST
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/11/2012 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
| 01/05/2012 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* 1) TEST WITH A 15 PSI GAUGE 2) CORRECT VENTING AT WATER HEATER/FURNACE 3) CORRECT SIZE AT 1/2" TEE 4) INSTALL A DRAIN PAN UNDER WATER HEATER, PIPE RELIEF VALVE TO PAN 5) ROTATE WATER HEATER SO CONTROL VALVE IS ACCESSIBLE |