Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA FINAL/BARRIER
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/21/2013 | POOL/SPA FINAL/BARRIER | Approved | IVRS - Inspection :* | |
| 02/06/2013 | POOL/SPA FINAL/BARRIER | Not ready for Inspection | IVRS - Inspection :* | |
| 02/04/2013 | POOL/SPA FINAL/BARRIER | Not ready for Inspection | IVRS - Inspection :*NEED LETTER FROM TEP REGARDING POWER LINES | |
| 01/15/2013 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999* BOND ANY METAL WITHIN 5' OF WATERS EDGE. POOL ENCLOSURE GATE LATCH 54" ABOVE GROUND OK RELEASE MECHANISM 5" BELOW TOP OF GATE. POOL BARRIER REQUIRED BETWEEN POOL AND OPENING GREATER THAN 4" FROM THE RESIDENCE OR LIVING SPACE. QUESTION: VERIFY OVERHEAD CONDUCTORS ARE 22 1/2 FEET FROM WATERS EDGE |