Permit: T12BU00526

Parcel: 11307147A

Inspection Status: Approved

Inspection History: POOL/SPA PLUMBING

Permit Number - T12BU00526

Inspection Description - POOL/SPA PLUMBING

Inspection Status - Approved

Date Description Inspector Results Comments
09/11/2012 POOL/SPA PLUMBING Approved IVRS - Inspection :*
07/16/2012 POOL/SPA PLUMBING Partial Approval 1. Be sure and use a listed purple primer when installing PVC pipe. 1" PVC water service from pool to equipment reinstalled OK. 2. Pool suction and return from pool to equipment area OK to cover.
07/09/2012 POOL/SPA PLUMBING Not ready for Inspection 1. There is no such thing as one step solvent cement for PVC pipe. PVC pipe and fittings are to have purple primer and approved solvent cement for the application.