Permit: T11PL02086

Parcel: 122020330


Addresses:

2238 N BELVEDERE AV

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
02/23/2012 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
02/22/2012 PLUMBING - GAS PRESSURE TEST Partial Approval IVRS - Inspection :*
1) PROVIDE ACCESS INSIDE
2) NOTE: 30 CALL AHEAD PROVIDED
3) SINGLE WALL MAY NOT BE USED AFTER TYPE B AND ALSO NOT OUTSIDE
4) EXTEND B VENT TO TERMINATE
02/17/2012 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE FULL SIZED PIPING
2) PROVIDE A SEPERATE VALVE FOR EACH
3) PROVIDE PROPER VENTING INSTALLED PER MANUFACTURER INSTRUCTIONS
3) TERMINATE ABOVE COOLER
02/08/2012 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
ETA AND 10 MINUTE CALL PROVIDED
PROVIDE MIN 3/4" PIPING TO SECURE BOTH WH & FURNACE
SECURE VENT CONNECTORS W/SCREWS
PROVIDE MIN 1" CLEARANCE AROUND B VENT
PROVIDE ELECTRICAL BONDING
YARD OK