Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/09/2011 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 12/06/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE MINIMUM 3 SCREWS AT ALL VENT PIPE JOINTS 2) PRESSURE TEST FAILED |
|
| 12/05/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) PIPE RELIEF VALVE WITH 3/4" PIPE 2) REMOVE TAPE FROM B VENT CONNECTION 3) CORRECT LEAKS AND PROVIDE TEST |
|
| 12/01/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE 10 PSI TEST ON ENTIRE GAS SYSTEM WITH TEST GAUGE IN 1/10 POUND INCREMENTS 2) PROVIDE SEDIMENT TRAP AT NEW WATER HEATER GAS PIPING AND COMPLETE WATER HEATER INSTALL 3) PROVIDE FASTENERS AT ALL VENT CONNECTOR JOINTS 4) REMOVE OLD GAS VALVE AND PROVIDE PERMANENT CAP ON GAS PIPING AT OLD FURNACE LOCATION 5) PROVIDE BONDING OF BLDG GAS SYSTEM |