Permit: T11PL01913

Parcel: 136291660


Addresses:

4875 S TAHOE PL

Inspection Status: Denied

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/02/2011 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE A MINIMUM 10 POUND TEST ON ENTIRE GAS SYSTEM
2) TEST GAUGE NOT TO EXCEED 15 POUND-1/10TH POUND INCREMENTS
3) PROVIDE AN APPROVED GAS SHUT OFF VALVE AT FURNACE
4) EXTEND WATER HEATER VENT 3' ABOVE COMBUSTION AIR INTAKE WITH DBL WALL VENT PIPE