Inspection History: PLUMBING - FINAL

Permit Number - T11PL01809

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
11/10/2011 PLUMBING - FINAL Approved
11/04/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) GAS FIRED WATER HEATER TO SIT ON AN APPROVED BASE
2) 3" ABOVE SURROUNDING GRDE
3) ENCLOSURE NOT MADE OF WEATHER PROOF MATERIAL
4) NO ACCESS TO WATER HEATER
5) ENCLOURE TO BE SECURED
6) FLEX MAY NOT PASS THRU ENCLOSURE
7) INSTALL VALVE
8) NO COMBUSTION RELIEF AND NO T & P RELIEF DRAIN
9) SHUT OFF ON COLD SIDE
11/02/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) THERE IS NO TRAILER NUMBERED #24 IN THIS PARK