Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/13/2012 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 06/26/2012 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* | |
| 05/24/2012 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) EXTEND PIPING AT FURNACE AND INSTALL APPROVED VALVE 2) WATER HEATER REQUIRES ENCLOSURE 3) COLD WATER INLET REQUIRES SHUT OFF VALVE 4) INSTALL APPROVED GAS VALVES WITH APPROVED FLEXES AND SEDIMENT TRAP 5) VENT CONNECTOR TO BE MADE UP PROPERLY 6) VENT CONNECTOR TO VENT TO BE MADE UP PROPERLY 7) VENT TO EXTEND FIVE FEET ABOVE WATER HEATER WITH APPROVED CAP 8) REQUIRE BOND BETWEEN METALLIC WATER AND GAS PIPE 9) REQUIRE 10 POUND TEST AT TIME OF INSPECTION |