Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/02/2011 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
| 11/01/2011 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE A 15 PSI GAUGE WITH A 10 PSI TEST 2) CORRECT WATER HEATER VENT CONNECTIONS 3) PROVIDE TYPE B VENT THRU ROOF 4) INSTALL FLASHINGS AT ALL ROOF PENETRATIONS 5) SECURE PIPING AND INSTALL SEDIMENT TRAPS 6) PROVIDE ELECTRICAL BONDING 7) PROVIDE AN OPERATIONAL SAFETY RELIEF VALVE |