Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T11PL01767

Parcel: 130056340


Addresses:

2717 E MENOR SV

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
11/02/2011 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
11/01/2011 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1) PROVIDE A 15 PSI GAUGE WITH A 10 PSI TEST
2) CORRECT WATER HEATER VENT CONNECTIONS
3) PROVIDE TYPE B VENT THRU ROOF
4) INSTALL FLASHINGS AT ALL ROOF PENETRATIONS
5) SECURE PIPING AND INSTALL SEDIMENT TRAPS
6) PROVIDE ELECTRICAL BONDING
7) PROVIDE AN OPERATIONAL SAFETY RELIEF VALVE