Permit: T11PL01680

Parcel: 11304169A


Addresses:

820 E PRINCE RD #01

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/28/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
10/26/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) EACH APPLIANCE REQUIRES A SHUT OFF VALVE AND RELIEF VALVES SHALL BE OPERATIONAL
2) SECURE VENT AND SUPPORT PIPING
3) UNIT 2, PROVIDE PROPERLY SIZED VENT WITH CLEARANCE
4) RELIEF VALVE TO EXTERIOR
10/20/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) BLK IRON PIPE MAY NOT BE INSTALLED UNDERGROUND. TAPING IS LIMITED TO SHORT SECTIONS STRIPPED FOR THREADING AND FITTINGS, PRIMER, THEN TAPE, HALF OVERLAPPED DBL WRAPPED
2) PROVIDE BOND BETWEEN WATER AND GAS PIPING
3) SEAL EXTERIOR WALL PENETRATIONS
4) USE APPROVED VALVES AGA OR CSA
5) AT GUEST HOUSE, 1" IS TO RUN TO FIRST TEE-MAY NOT REDUCE MID-STREAM
6) EXTEND T & P RELIEF DRAIN
10/17/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) CANCELLED PER HOMEOWNER