Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/28/2011 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 10/26/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) EACH APPLIANCE REQUIRES A SHUT OFF VALVE AND RELIEF VALVES SHALL BE OPERATIONAL 2) SECURE VENT AND SUPPORT PIPING 3) UNIT 2, PROVIDE PROPERLY SIZED VENT WITH CLEARANCE 4) RELIEF VALVE TO EXTERIOR |
|
| 10/20/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) BLK IRON PIPE MAY NOT BE INSTALLED UNDERGROUND. TAPING IS LIMITED TO SHORT SECTIONS STRIPPED FOR THREADING AND FITTINGS, PRIMER, THEN TAPE, HALF OVERLAPPED DBL WRAPPED 2) PROVIDE BOND BETWEEN WATER AND GAS PIPING 3) SEAL EXTERIOR WALL PENETRATIONS 4) USE APPROVED VALVES AGA OR CSA 5) AT GUEST HOUSE, 1" IS TO RUN TO FIRST TEE-MAY NOT REDUCE MID-STREAM 6) EXTEND T & P RELIEF DRAIN |
|
| 10/17/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED PER HOMEOWNER |