Permit: T11PL01608

Parcel: 110061960


Addresses:

4131 E GLENN ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/13/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
11/17/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) REMOVE DAMAGED B VENT, INSTALL SINGLE WAY CONNECTORS. SECURE EACH JOINT WITH SCREWS
2) CPVC IS OK FOR RELIEF DRAIN PIPING
11/09/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) NO ANSWER 2:45 PM
10/04/2011 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
14 PSI TEST IS OK. LEFT GAS CARD
10/03/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PROVIDE APPROVED GALV VENT CONNECTORS ON WATER HEATER
2) PROVIDE CITY APPROVED RELIEF DRAIN
3) PIPE GAS VALVE AND FLEX INTO ACCESS PANEL OF WALL FURNACE
4) BOND GAS PIPING