Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/14/2011 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1) CORRECTIONS MADE OK 2) OK FOR GAS 3) UCC LEFT AT METER |
|
| 10/11/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE A MOBILE HOME FLEX AT CONNECTION TO M.H. 2) RELOCATED WATER HEATER REQUIRES ONE SOLID APPROVED SUPPORTING BASE 3 1/2" ABOVE GRADE AND TYPE B VENT. CU (METAL) CLAMPS ARE NOT TO BE USED ON PEX UNLESS DESIGNED FOR SUCH USE |
|
| 10/06/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 09/27/2011 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* 1) NEW GAS LINE FROM METER TO MANHOLE OK-OK TO COVER 2) AT MANHOLE FLEX MAY NOT BE USED IN LIEU OF HARD PIPE 3) WATER HEATER MOVED OUTSIDE AT SOME POINT. VENT NOT APPROVED 4) MAKE ALL CORRECTIONS AND TEST ENTIRE SYSTEM |