Permit: T11PL01603

Parcel: 138190800

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/25/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
10/13/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) WATER HEATER IS RELOCATED
2) PROVIDE DBL WALL VENT PIPING LEAVING INCLOSURE THRU ROOF TO TERMINATION AT VENT CAP
3) HARD PIPE GAS PIPING INTO INCLOSURE, NO GAS FLEX THRU SIDE WALL OF INCLOSURE
4) PROPERLY SEAL INSULATION ON ALL POTABLE PIPING EXPOSED TO FREEZING AND PROTECT INSULATION FROM UV EXPOSURE
5) HAVE SOMEONE ON SITE FOR REINSPECTION TO SOAP TEST GAS PIPE CORRECTION