Permit: T11PL01577

Parcel: 11307275A


Addresses:

1321 E GLENN ST #02

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/11/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
09/29/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) CORRECT CW RISER AS NOTED
2) STEEL MALE PIPE THREADS MAY NOT BE USED WITH PLASTIC FEMALE THREADS
3) PROVIDE A CODE APPROVED TRANSITION FITTING OF FLEX CONNECTOR
09/22/2011 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REMOVE B VENT TRANSITION ADAPTOR AND CONNECT VENT AND DRAFT HOOD PROPERLY
2) PROVIDE THE MINIMUM REQUIRED CLEARANCE AROUND BO VENT AT ROOF PENETRATION
3) COPPER MAY NOT BE DIRETLY CONNECTED TO GALVANIZED WITHOUT DIELECTRIC OR BRASS SEPERATION
4) 1/2" PEX IS UNDERSIZED AND NOT PROPERLY INSTALLED
5) 3/4 REPAIR COUPLING ON SUPPLY RISER MAY NOT BE USED WITHOUT RESTRAINT
6) PROVIDE A SOLID PIPE CONNECTION
7) SUPPORT/SECURE GAS SUPPLY PIPE