Permit: T11PL01570

Parcel: 125111130


Addresses:

3618 E 2ND ST #07

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/21/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
1) 15 PSI TEST
2) LEFT GAS CARD
09/28/2011 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) EXPOSE ALL NEW PIPE
2) BURIED GAS PIPE MUST BE SCOTCH COATED PIPE
3) ALL FITTINGS AND TOOL MARKS MUST BE PRIMERED AND TAPED WITH 40 MILS OF TAPE
4) TAPES AND PRIMERS MUST BE UPC APPROVED
5) USE APPROVED GAS SHUT OFF VALVES AT APPLIANCES
6) RECOMMEND USING A LICENSED CONTRCTOR