Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/17/2011 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 10/06/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* SEE ALLL NOTES & COMPLY |
|
| 10/03/2011 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) THE VENT CONNECTOR PIPING NEEDS TO BE INSTALLED WITHOUT HOLES OR VOIDS IN CONNECTIONS 2) REMOVE ALL THE TAPE 3) THE LOWER VENT PIECE GOES INTO THE UPPER SECTION AT EACH JOINT AND REQUIRES SCREWS OR RIVETS TO SECURE EACH VENT JOINT 4) VENT MUST BE MINIMUM 5' FROM DRAFT HOOD TO TERMINATION AT APPROVED VENT CAP |
|
| 09/29/2011 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROPERLY INSTALL THE WATER HEATER DRAFT HOOD AND VENT FROM WATER HEATER 2) REMOVE THE TAPE ON THE WATER HEATER VENT 3) VERIFY PROPERLY CONNECT WITH FASTENERS AT VENT JOINTS |
|
| 09/28/2011 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE 3/4" TEMPERATURE AND PRESSURE RELIEF DRAIN PIPING TERMINATING DOWN 2) PROVIDE STRUCTURAL SUPPORTS UNDER WATER HEATER FLOOR AS REQUIRED FROM 9/22/11 INSPECTION 3) DRAFT HOOD TO BE INSTALLED CORRECTLY AND VENTED CORRECTLY |
|
| 09/22/2011 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE A GAS WATER HEATER LISTED FOR MOBILE HOME USE, WITH AN APPROVED TEMPERATURE AND PRESSURE RELIEF DRAIN PIPE TO EXTERIOR TERMINATING 6"-24" FROM FINISH GRADE AT DOWNWARD ANGLE USE GALV PIPE, CPVC OR COPPER WITH NO THREADS ON DISCHARGE END 2) THE FLOOR OF THE WATER HEATER CLOSET IS NOT SUPPORTED CORRECTLY TO HOLD UP THE WATER HEATER PROPERLY. MAKE CORRECTION TO FLOOR AND STRUCTURAL SUPPORT TO WITHSTAND WEIGHT OF WATER HEATER |