Permit: T11PL01495

Parcel: 122081690


Addresses:

2207 N COLUMBUS BL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
09/16/2011 PLUMBING - FINAL Approved
09/13/2011 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 15 PSI TEST OK
2) IN ORDER TO GET THE GAS CLEARANCE CARD YOU WILL NEED TO PROVIDE A PERMIT FOR THE NEW A/C, FURNACE AND WATER HEATER. THE WATER HEATER WILL PASS INSPECTION, HOWEVER THE FURNACE WILL NEED A HOSE CLAMP ON CONDENSATE PUMP DISCHARGE
2) TERMINATE 3/8" DRAIN HOSE INTO THE HORIZONTAL SECTION OF THE CONDENSATE DRAIN LINE WHICH WILL NEED TO BE INCREASED TO 3/4"
3) USE LISTED OUTDOOR TAPE ON THE EXPOSED ARMAFLEX ON THE ROOF
4) EXTEND THE FURNACE VENT MINIMUM 3' ABOVE THE COMBUSTION AIR INTAKE
5) PROVIDE THE REQUIRED DRAWING FOR NEW A/C UNIT ON THE ROOF
6) PROVIDE ACCESS TO THE ROOF FOR INSPECTION
7) TERMINATE THE CONDENSATE DRAIN WITH AN ELBOW AT END OF DISCHARGE AND A NIPPLE TO DIVERT THE WATER AWAY FROM THE HOUSE