Permit: T11PL01468

Parcel: 125160660

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
09/15/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
09/13/2011 PLUMBING - FINAL Cancelled IVRS - RI canceled
09/08/2011 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1) 11 PSI TEST IS OK AND LEFT GAS CARD
2) REMOVE ALL STONEY DIRT FROM TRENCH
3) PROVIDE A FIRM BED OF CLEAN FILL AND HAVE EITHER A SCREEN ON SITE OR ENOUGH CLEAN FILL TO PROVIDE 12" OF COVER. NO STONES ALLOWED
4) PROVIDE MINIMUM 3 SCREWS IN ALL JOINTS OF WATER HEATER VENT
5) REMOVE THE ABANDONED GAS RISER AT METER
6) NO PERMIT FOR NEW FURNACE AND A/C