Permit: T11PL01433

Parcel: 127020270


Addresses:

5322 E ROSEWOOD ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
09/01/2011 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
08/31/2011 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE PROPER RELIEF DRAIN TERMINATION
2) SECURE VENT PIPING WITH GALVANIZED SCREWS
3) REPLACE GAS FLEX AND INSTALL A SEDIMENT TRAP AT WATER HEATER AND FURNACE INLET
4) PROVIDE ELECTRICAL BONDING
5) PROVIDE A TEST WITH A 15 PSI GAUGE
6) FIRE PLACE REQUIRES AN EXTERNAL SHUT OFF VALVE
7) REMOVE THREAD PROTECTOR AND INSTALL A LISTED PIPE COUPLING OR UNION