Permit: T11PL01412

Parcel: 132180300


Addresses:

1134 E TENNESSEE ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/04/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
09/13/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PROVIDE ROOF FLASHINGS AT ALL PIPE PENETRATIONS THRU ROOF MADE WEATHER TIGHT (3)
2) PROVIDE WEATHER RESISTANT BLOCKING TO SUPPORT PIPING ACROSS ROOF WITH WEATHER RESISTANT SCREWS
3) PROVIDE VACUUM BREAKERS AT ALL HOSE BIBS
4) PROVIDE INSULATION ON ALL PIPING EXPOSED TO FREEZING, INSULATION TO BE SEALED & IF ARMAFLEX IS USED TO BE PROTECTED FROM U.V. EXPOSURE (PAINTED)