Permit: T11PL01386

Parcel: 138071890


Addresses:

958 W CALLE RAMONA

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
09/01/2011 PLUMBING - FINAL Approved
08/31/2011 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE A SEDIMENT TRAP AT GAS ENTRY TO WATER HEATER
2) PROVIDE WATER HEATER TEMPERATURE AND PRESSURE RELIEF APPROVED PIPING GRAVITY DRAIN TO EXTERIOR TERMINATING AT 90 DEGREE DOWN 6" TO 24" FROM FINISH GRADE
3) REMOVE ALL TAPE FROM VENT PIPING, PROVIDE 1" MINIMUM CLEARANCE FROM COMBUSTIBLES AT ROOF LINE, SEALL ROOF JACK WEATHER TIGHT AND PROVIDE APPROVED VENT CAP AT TERMINATION