Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T11PL01347
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/26/2011 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
08/23/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* NO ACCESS TO BACKFLOR/CERTIFICATION AT 2:16 |
|
08/19/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* OK TO SHEET ROCK PROVIDE APPROVED BACKFLOW PROTECTION FOR IRRIGATION SUPPLY, REDUCED PRESSURE BACKFLOW ASSEMBLY, PRESSURE VACUUM BREAKER WITH CERTIFICATION |
|
08/16/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) WATER HAMMER ARRESTORS REQUIRED AT WB 2) KEEP OPEN PIPES (SEWER) CAPPED DURING CONSTRUCTION FOR SAFETY 3) METAL 2 HOLE CLAMPS ARE NOT ALLOWED ON PEX-PROVIDE APPROVED PIPE SUPPORTS 4) SECURE ALL TUBING AS REQUIRED PER CODE 5) PROVIDE VACUUM BREAKERS ON ALL HOSE BIBS 6) PROVIDE APPROVED BACKFLOW PROTECTION AT IRR SUPPLY 7) CORRECT DW DRAIN HOSE-SECURE AS HIGH AS POSSIBLE OR AG 8) REMOVE EXCESS FLEX AT SOLDIER JOINTS 9) ISOLATE BETWEEN HW AND CW TO PREVENT NOISE |