Permit: T11PL01347

Parcel: 133501940

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T11PL01347

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
08/26/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
08/23/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
NO ACCESS TO BACKFLOR/CERTIFICATION AT 2:16
08/19/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
OK TO SHEET ROCK
PROVIDE APPROVED BACKFLOW PROTECTION FOR IRRIGATION SUPPLY, REDUCED PRESSURE BACKFLOW ASSEMBLY, PRESSURE VACUUM BREAKER WITH CERTIFICATION
08/16/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) WATER HAMMER ARRESTORS REQUIRED AT WB
2) KEEP OPEN PIPES (SEWER) CAPPED DURING CONSTRUCTION FOR SAFETY
3) METAL 2 HOLE CLAMPS ARE NOT ALLOWED ON PEX-PROVIDE APPROVED PIPE SUPPORTS
4) SECURE ALL TUBING AS REQUIRED PER CODE
5) PROVIDE VACUUM BREAKERS ON ALL HOSE BIBS
6) PROVIDE APPROVED BACKFLOW PROTECTION AT IRR SUPPLY
7) CORRECT DW DRAIN HOSE-SECURE AS HIGH AS POSSIBLE OR AG
8) REMOVE EXCESS FLEX AT SOLDIER JOINTS
9) ISOLATE BETWEEN HW AND CW TO PREVENT NOISE