Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/18/2011 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 08/16/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) REMOVE THE FUTURE TEE CONNECTION AT WATEE HEATER/FURNACE AREA 2) PIPING TO BE ARRANGED SO WATER HEATER CAN BE REMOVED WITHOUT DISASSEMBLY OF PIPING 3) PROVIDE BONDING OF BLDG GAS SYSTEM 4) VERIFY GAUGE IS FUNCTIONAL AND ENTIRE SYSTEM HOLDS 10 PSI WITH NO LOSS FOR 15 MINUTES |
|
| 08/11/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) CONNECT YARD PIPING TO HOUSE AND TEST THE ENTIRE SYSTEM 2) NO DRIP LEG AT FURNACE OR WATER HEATER 3) PROVIDE BOND BETWEEN WATER AND GAS |