Permit: T11PL01324

Parcel: 133393780


Addresses:

9821 E AMAROSO LN

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
08/16/2011 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
08/15/2011 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) AN ATMOSPHERIC VACUUM BREAKER MAY NOT HAVE VALVES DOWNSTREAM
2) 18" OF COPPER REQUIRED AT CONCEALED ? CONNECTIONS
3) ADHESIVE TAPE NOT ALLOWED ON PEX
4) ISOLATE AND SECURE TUBING IN WALLS
5) SUPPORT AND SECURE PED AT 32"
6) LEAVE LADDER ON SITE FOR NEXT INSPECTION