Permit: T11PL01315

Parcel: 136161690

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
09/16/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
09/15/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PROVIDE A #4 OR #6 BONDING WIRE (SOLID)
2) MAKE UP THE WYE FITTING CORRECTLY INTO THE DBL WALL VENT PIPE ABOVE WATER HEATER
3) GAS CARD AT METER
09/06/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) SECURE PIPING
2) RELIEF VALVE MAY NOT BE TRAPPED, PIPE WITH APPROVED MATERIALS
3) PE REQ 18" OF COVER
4) ROOF PENETRATION REQUIRES A FLASHING
5) REMOVE CHECK VALVE ON CW SUPPLY TO WH OR INSTALL AN EXPANSION TANK
6) BOND GAS LINE