Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/03/2011 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 08/02/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) REMOVE THE FUTURE TEE CONNECTION OR PROVIDE PLAN FOR ITS USE 2) TEST TO HOLD WITH NO LOSS OF PRESSURE 3) BLACK FITTINGS TO BE PRIMED WITH PIPE TAPE PRIMER, THEN WRAPPED WITH PIPE TAPE WRAP TO ACHIEVE 40 MIL THICKNESS OF WRAP 4) PROVIDE AN APPROVED ROOF FLASHING WHERE PIPE PENETRATIONS THRU ROOF 5) ARRANGE PIPING IN CLOSET SO DOOR CLOSES WITHOUT HITTING PIPING AND SO BOTH APPLIANCES CAN BE REMOVED WITHOUT PIPE DIS-ASSEMBLY 6) PROVIDE BONDING OF GAS SYSTEM |
|
| 07/29/2011 | PLUMBING - FINAL | Cancelled | CANCELLED PER OWNER BRETT #548-5023 | |
| 07/29/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* |