Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/08/2014 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 04/05/2012 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 1" CLEARANCE REQUIRED AT ROOF PENETRATION 2) TYPE B VENT REQUIRED FROM ENCLOSURE TO POINT OF TERMINATION MINIMUM 1' ABOVE ROOF, INSTALL IN PROPER DIRECTION OF FLOW 3) CONNECT VENT CONNECTOR TO DRAFT COLLAR 4) PROTECT ALL WATER PIPING OUTSIDE FROM FREEZE DAMAGE 5) GAS CARD PROVIDED |
|
| 12/01/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) B VENT REQUIRED, ALSO APPROVED SUPPORTS GAS FLEX MAY NOT PENETRATE ENCLOSURE 2) REMOVE HB FROM CLEANOUT 3) COMPLETE INTERIOR PLUMBING 4) INSTALL VALVE WITH CAP AT STOVE LOCATION |
|
| 08/03/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) IRRIGATION CONNECTION REMOVED 2) NEED WATER HEATER INSALL AND INSULATION ON PIPING |
|
| 07/29/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE APPROVED BACKFLOW PROTECTION FOR IRRIGATION CONNECTION 2) PROVIDE ISOLATION FROM BANG PLATE, SECURE PIPING AND ISOLATE FROM C1 3) HAMMER ARRESTORS REQUIRED 4) WATER HEATER NOT INSTALLED 5) LAUNDRY TRAP ARM LIMITED TO 90 DEGREE AND 5' 6) YARD LINES OK TO COVER AFTER REMAINING ROCKS (BOTH) |